It is 3 4 pvc and has a p trap and tee s into the bathroom sink vent in the attic.
Qc in attic no condensate pump.
The amount of condensate the unit produces varies increasing as the outdoor humidity level rises.
Central air conditioners produce something other than cool comfort.
You can heat tape but your chances still exist for problems.
The old pvc drain had a vent immediately behind the p trap which consisted of a t pointing up with a 6 piece of pvc glued in it.
Except no one dwells in the attic as much as a basement.
Air conditioners pull humidity out of the air and funnel the resulting water or condensate into a drain.
Most updated central air conditioned homes have a new air conditioner split system meaning the ac is broken up into parts.
And what the heck is it.
The vent was taped closed when i bought the house.
Had a new air handler put in the attic and i need to hook up the condensate drain.
Air conditioner condensate pumps are a convenient way to collect and dispose of the condensate produced by an air conditioning system when the air handler cooling coil are located in a building location where the cooling condensate cannot be drained away by gravity.
Attic hvac systems save space.
Hopefully that will stop wet spots in case of failure.
An outdoor unit which houses the fan condenser and compressor and an indoor unit which holds the evaporator and fan.
Water lots of it.
See those copper lines going into your hvac system.
So the first sign the condensate pump took a crap is a wet spot on the ceiling.
If your air conditioner is not working and the furnace or air handler is located in your attic you will need to inspect the drain pain located directly underneath the evaporator coil in your air conditioning system.
This humidity turns into condensation which can back up in a drain pan connected to the indoor portion of your air conditioner.
90 furnaces still have an issue even if the drain don t freeze long periods of non use can make condensate problems within the heat exchanger.
Attached to those copper lines is your evaporator coil.
This is where the job of the condensate line comes in.
So why put an hvac system up in the attic at all.
The water that drains from a central air conditioning unit is condensate that has accumulated on the cooling coils within the unit.
Yes this is why i have such distain for 90 furnaces in an attic.
This pump has a secondary float switch to shut the system down if the pump fails.
Condensate pumps air conditioning condensate pump installation repair.
Problems with a central air conditioner s condensate drain.
Well mainly it s a way to save space.
I ve also seen heat tape warp pvc pipe sort of spiral like a unicorn.